dc.contributor.author | Cintra Pastó, Didiet | |
dc.contributor.advisor | Rodríguez Pérez, Dr. C. Suyén P T | |
dc.date.accessioned | 2023-11-30T14:38:31Z | |
dc.date.available | 2023-11-30T14:38:31Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | http://repositorio.uo.edu.cu/handle/123456789/1307 | |
dc.description | Este documento es Propiedad Patrimonial de la Universidad de Oriente de Santiago de Cuba. Los autores conservan los derechos morales que como tal le son reconocidos por la Legislación vigente sobre Derecho de Autor. Los distintos Usuarios podrán copiar, distribuir, comunicar públicamente la obra y hacer obras derivadas; bajo las condiciones siguientes:
1. Reconocer y citar al autor original
2. No utilizar la obra con fines comerciales
3. No realizar modificación alguna a la obra
4. Compartir aquellos productos resultado del uso de la obra bajo la misma licencia de esta
5. Los Usuarios pueden reutilizar los metadatos en cualquier medio sin autorización previa, siempre que los propósitos de su utilización sean sin ánimo de lucro y se provea el Identificador OAI, un enlace al registro de metadatos original, o se haga referencia al repositorio de donde han sido extraídos
Todo lo anterior está en correspondencia con las legislaciones vigentes sobre Derecho de Autor. | es_ES |
dc.description.abstract | El ior® Hemo-CIM anti-D, es un reactivo hemoclasificador empleado en Bancos de sangre y servicios de transfusiones para la identificación del sistema Rh. En el LABEX, este producto, se formula a partir de la dilución de los sobrenadantes de cultivo, que contienen los anticuerpos IgM (anti-D) e IgG (anti-D débil (Du)). Este reactivo ha presentado una alta variabilidad en los valores de potencia de aglutinación y la avidez, lo cual pone en riesgo el cumplimiento de los requisitos de calidad y la percepción del cliente sobre el reactivo. En este trabajo se realizó una evaluación del Hemoclasificador anti-D, basado en el criterio de concentración de los anticuerpos IgM e IgG en los sobrenadantes anti-D y anti-D débil (Du) y su incidencia en los valores de potencia, avidez a intensidad de la aglutinación según las especificaciones ESP-5032 y ESP-5033 en cada uno de los experimentos. Se evaluó además el efecto de los componentes del Buffer en estos indicadores de calidad. Se realizó la caracterización de ambas moléculas (IgM e IgG) por cromatografía (HPLC), demostrándose que el efecto más significativo sobre los parámetros de potencia y avidez, resultó la concentración de IgM. Por lo tanto, se determinó la concentración mínima de IgM de 0.035 mg/mL en el formulado y un intervalo de IgG en 0,048 ± 0,003 mg/mL. Se determinó la influencia de las sales, principalmente en la avidez, estableciendo una propuesta de 4 g/L para la formulación. Con la incorporación de la determinación de concentración de Ig y las propuestas de mejoras en cuanto a componentes del formulado, se logra mejorar el desempeño económico, por cuanto se incrementan los ingresos por producto final vendido. | es_ES |
dc.description.sponsorship | The ior® Hemo-CIM anti-D is a hemoclassifier reagent used in blood banks and transfusion services for the identification of the Rh system. In LABEX, this product is formulated from the dilution of culture supernatants, which contain IgM (anti-D) and IgG (anti-D débil (Du)) antibodies. This reagent has presented a high variability in the agglutination potency values and avidity, which puts at risk the fulfillment of the quality requirements and the customer's perception of the reagent. In this work, an evaluation of the anti-D Hemoclassifier was carried out, based on the criterion of concentration of IgM and IgG antibodies in the anti-D and anti-D débil (Du) supernatants and their incidence in the potency, avidity values the intensity of the agglutination according to the ESP-5032 and ESP-5033 specifications in each of the experiments. The effect of the Buffer components on these quality indicators was also evaluated. The characterization of both molecules (IgM and IgG) was carried out by chromatography (HPLC), showing that the most significant effect on the power and avidity parameters was the IgM concentration. Therefore, the minimum IgM concentration of 0.35 mg / mL in the formulation and an IgG range of 0.048 ± 0.003 mg / mL were determined. The influence of the salts was determined, mainly in the avidity, establishing a proposal of 4 g / L for the formulation. With the incorporation of the determination of Ig concentration and the proposals for improvements in terms of formulation components, it is possible to improve the economic performance, since the income per final product sold is increased. | es_ES |
dc.language.iso | es | es_ES |
dc.publisher | Centro de Estudios de Biotecnología Industrial. Universidad de Oriente. Cuba | es_ES |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.subject | ANTICUERPO MONOCLONAL | es_ES |
dc.subject | ANTÍGENO | es_ES |
dc.subject | CROMATOGRAFÍA LÍQUIDA DE ALTA RESOLUCIÓN | es_ES |
dc.subject | GRUPOS SANGUÍNEOS | es_ES |
dc.subject | HEMAGLUTINACIÓN | es_ES |
dc.subject | INMUNOGLOBULINAS | es_ES |
dc.subject | SOBRENADANTES DE CULTIVO | es_ES |
dc.subject | MONOCLONAL ANTIBODY | es_ES |
dc.subject | ANTIGEN | es_ES |
dc.subject | HIGH RESOLUTION LIQUID CHROMATOGRAPHY | es_ES |
dc.subject | POLYACRYLAMIDE GEL ELECTROPHORESIS | es_ES |
dc.subject | BLOOD GROUPS | es_ES |
dc.subject | HEMAGGLUTINATION | es_ES |
dc.subject | IMMUNOGLOBULINS | es_ES |
dc.subject | CULTURE SUPERNATANT | es_ES |
dc.title | Evaluación de mejoras a la formulación del Hemoclasificador anti-D a partir de las concentraciones del Ingrediente Farmacéutico Activo | es_ES |
dc.title.alternative | Evaluation of improvements to the formulation of the anti-D Hemoclassifier from the concentrations of the Active Pharmaceutical Ingredient | es_ES |
dc.type | Tesis | es_ES |